← Evidence library

Lidwell ultraclean air

Effect of ultraclean air in operating rooms on deep sepsis in the joint after total hip or knee replacement: a randomised study.

Lidwell OM, Lowbury EJ, Whyte W, et al. British medical journal (Clinical research ed.) 1982 · PMID 6805791 · doi:10.1136/bmj.285.6334.10

Randomised trialPreventionOperative technique & equipmentCitation checked
Question
Does operating in ultraclean (laminar flow) air reduce deep joint infection after hip and knee replacement?
Design
Multicentre MRC study in which each surgeon's operations were randomly allocated between ultraclean-air and conventional theatres.
Patients
Patients having total hip or knee replacement.
Intervention
Ultraclean air ventilation, with or without body-exhaust suits
Comparison
Conventional theatre ventilation
Primary outcome
Deep joint sepsis
Key result
Deep joint sepsis was roughly halved with ultraclean air and reduced further when whole-body exhaust suits were also worn; prophylactic antibiotic use was associated with lower sepsis, though this was not tested in a controlled way.
Limitations
Predates modern antibiotic protocols and implants; randomisation was by operation within surgeons rather than strictly at patient level, and the antibiotic effect was observational.
Impact on practice
It is the foundation for laminar flow theatres in UK arthroplasty and remains a frequently examined classic.