← Evidence libraryLidwell ultraclean air
Effect of ultraclean air in operating rooms on deep sepsis in the joint after total hip or knee replacement: a randomised study.
Lidwell OM, Lowbury EJ, Whyte W, et al. British medical journal (Clinical research ed.) 1982 · PMID 6805791 · doi:10.1136/bmj.285.6334.10
Randomised trialPreventionOperative technique & equipmentCitation checked
- Question
- Does operating in ultraclean (laminar flow) air reduce deep joint infection after hip and knee replacement?
- Design
- Multicentre MRC study in which each surgeon's operations were randomly allocated between ultraclean-air and conventional theatres.
- Patients
- Patients having total hip or knee replacement.
- Intervention
- Ultraclean air ventilation, with or without body-exhaust suits
- Comparison
- Conventional theatre ventilation
- Primary outcome
- Deep joint sepsis
- Key result
- Deep joint sepsis was roughly halved with ultraclean air and reduced further when whole-body exhaust suits were also worn; prophylactic antibiotic use was associated with lower sepsis, though this was not tested in a controlled way.
- Limitations
- Predates modern antibiotic protocols and implants; randomisation was by operation within surgeons rather than strictly at patient level, and the antibiotic effect was observational.
- Impact on practice
- It is the foundation for laminar flow theatres in UK arthroplasty and remains a frequently examined classic.