Revision notes โ€บ Hip arthroplasty

Dislocation after hip arthroplasty

Dislocation is one of the commonest early complications of total hip arthroplasty and a leading reason for revision. It results from a mix of patient, surgical and implant factors, and recurrent instability needs a careful search for the cause rather than repeated reductions.

Key points

  • Most dislocations occur early; direction usually follows the surgical approach.
  • Risk factors are patient, surgical and implant related; identify which apply before treating.
  • Document sciatic nerve function before and after any reduction.
  • CT measures cup and stem version accurately in recurrent instability.
  • Always exclude infection in late or recurrent instability.
  • Revision is cause-directed: correct malposition, offset, impingement or use dual mobility or constraint.
  • Capsular and short external rotator repair reduces dislocation after a posterior approach.

The basics

A hip replacement dislocates when the femoral head levers or slides out of the acetabular component. Most dislocations happen in the first few months, before the soft tissues heal and a pseudocapsule forms, but late dislocation can follow polyethylene wear, abductor failure or a fall.

The direction usually reflects the approach: posterior dislocation after a posterior approach, occurring in flexion, adduction and internal rotation (for example rising from a low chair); anterior dislocation is less common and occurs in extension and external rotation.

After a first dislocation, a substantial proportion of patients go on to dislocate again, and recurrent instability is a major source of morbidity and revision surgery.

Risk factors

Think in three groups.

  • Patient: older age, female sex, neuromuscular disease (Parkinson's disease, previous stroke), cognitive impairment, alcohol misuse, previous hip surgery, hip fracture as the indication, and a stiff lumbar spine or previous spinal fusion.
  • Surgical: posterior approach without soft tissue repair, component malposition (cup retroversion or excessive anteversion, too vertical or too horizontal), inadequate restoration of offset or leg length, impingement of bone or osteophyte, and surgeon inexperience.
  • Implant: small femoral head (lower head-neck ratio and less jump distance), skirted heads, and polyethylene wear in older implants.

Revision surgery has a substantially higher dislocation risk than primary surgery.

Never miss

  • Sciatic or peroneal nerve deficit before or after reduction.
  • Irreducible dislocation or dislocation with component failure or periprosthetic fracture.
  • Instability with raised inflammatory markers or wound problems: consider prosthetic joint infection.

Common pitfalls

  • Repeated forceful closed reduction attempts causing fracture or nerve injury.
  • Assuming a cup inside the Lewinnek zone is safe in a patient with a fused or stiff spine.
  • Revising for recurrent instability without identifying the cause.
  • Forgetting intraprosthetic dislocation of a dual mobility bearing after closed reduction.